|
|
Inappropriate
|
See Answer
To Email:
Subject:
Note to go along with the question: (Optional, no
more than 1,000 characters)
COMP is a binary storage format while COMP-3 is packed decimal format.
Create Date
:
Friday, May 09, 2008
Click here
to improve the Interview Question, Answer and other fields.
|
|
Inappropriate
|
See Answer
To Email:
Subject:
Note to go along with the question: (Optional, no
more than 1,000 characters)
In the most significant bit. Bit is on if -ve, off if +ve.
Create Date
:
Friday, May 09, 2008
Click here
to improve the Interview Question, Answer and other fields.
|
|
Inappropriate
|
See Answer
To Email:
Subject:
Note to go along with the question: (Optional, no
more than 1,000 characters)
It is stored in the last nibble. For example if your number is +100, it stores hex 0C in the last byte, hex 1C if your number is 101, hex 2C if your number is 102, hex 1D if the number is -101, hex 2D if the number is -102 etc.
Create Date
:
Friday, May 09, 2008
Click here
to improve the Interview Question, Answer and other fields.
|
|
Inappropriate
|
See Answer
To Email:
Subject:
Note to go along with the question: (Optional, no
more than 1,000 characters)
Packed Decimal fields: Sign is stored as a hex value in the last nibble (4 bits ) of the storage. Zoned Decimal fields: As a default, sign is over punched with the numeric value stored in the last bite.
Create Date
:
Friday, May 09, 2008
Click here
to improve the Interview Question, Answer and other fields.
|
|
Inappropriate
|
See Answer
To Email:
Subject:
Note to go along with the question: (Optional, no
more than 1,000 characters)
Basically you need to correcting the offending data.
Many times the reason for SOC7 is an un-initialized numeric item. Examine that possibility first.
Many installations provide you a dump for run time abends ( it can be generated also by calling some subroutines or OS services through assembly language). These dumps provide the offset of the last instruction at which the abend occurred. Examine the compilation output XREF listing to get the verb and the line number of the source code at this offset. Then you can look at the source code to find the bug. To get capture the runtime dumps, you will have to define some datasets (SYSABOUT etc ) in the JCL.
If none of these are helpful, use judgment and DISPLAY to localize the source of error.
Some installation might have batch program debugging tools. Use them.
Create Date
:
Friday, May 09, 2008
Click here
to improve the Interview Question, Answer and other fields.
|
|
Inappropriate
|
See Answer
To Email:
Subject:
Note to go along with the question: (Optional, no
more than 1,000 characters)
Be the first one to answer the question